Injection Needles

These injection needles are designed for use in bronchoscopy, gastroscopy and colonoscopy. They come with a safety clip to enable safe placement even in angled positions.

Transparent needle tubes allow to check the introduced liquids. A special locking mechanism ensures a controlled puncture in the target tissue.

Needles include: 

  • ECO-Injectra
  • Injectra

Injection Needles – Single Use Leaflet 

Technical Details

Bronchoscopy – ECO-Injectra

Metal tip protection; needle locking mechanism (one hand operation)

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-21-18-1200.5/2541.81202.0
GSN-22-18-1200.5/2561.81202.0

Gastroscopy – ECO-Injectra

Metal tip protection; needle locking mechanism (one hand operation)

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-21-23-1800.5/2542.31802.8
GSN-23-23-1800.7/2242.31802.8
GSN-25-23-1801.0/1942.31802.8
GSN-22-23-1800.5/2542.31802.8
GSN-24-23-1800.7/2242.31802.8
GSN-26-23-1801.0/1942.31802.8

Colonoscopy – ECO-Injectra

Metal tip protection; needle locking mechanism (one hand operation)

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-21-23-2300.5/2542.32302.8
GSN-23-23-2300.7/2242.32302.8
GSN-25-23-2301.0/1942.32302.8
GSN-22-23-2300.5/2562.32302.8
GSN-24-23-2300.7/2262.32302.8
GSN-26-23-2301.0/1962.32302.8

Bronchoscopy – Injectra

Removable safety clip; Luer-Lock-mechanism

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-03-19-1200.7/2261.91202.2
GSN-04-23-1201.0/1962.31202.8

Gastroscopy – Injectra

Removable safety clip; Luer-Lock-mechanism

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-03-19-1600.7/2261.91602.2
GSN-05-19-1800.5/2541.91802.2
GSN-01-19-1800.7/2241.91802.2
GSN-06-19-1800.5/2561.91802.2
GSN-03-19-1800.7/2261.91802.2
GSN-04-23-1601.0/1962.31602.8
GSN-02-23-1801.0/1942.31802.8
GSN-04-23-1801.0/1962.31802.8

Colonoscopy – Injectra

Removable safety clip; Luer-Lock-mechanism

Catalogue No.Needle Diameter (mm / Gauge)Needle Length (mm)Sheath Outer Diameter (mm)Working Length (cm)Min. Accessory Channel (mm)
GSN-03-19-2100.7/2261.92102.2
GSN-05-19-2300.5/2541.92302.2
GSN-01-19-2300.7/2241.92302.2
GSN-06-19-2300.5/2561.92302.2
GSN-03-19-2300.7/2261.92302.2
GSN-02-23-2301.0/1942.32302.8
GSN-04-23-2301.0/1962.32302.8