ARIS◊ COBLATION◊ TURBINATE REDUCTION WAND

Ablate at the rate you need!

Designed for versatility, the ARIS COBLATION Turbinate Reduction Wand allows the degree of tissue removal to be varied when treating hypertrophic turbinates submucosally, depending on the patient indication. Utilising advanced COBLATION Plasma Technology, it provides a minimally invasive procedure with:

  • Visibility: Intraoperative, visual reduction of the turbinate4
  • Hemostasis: Targeted hemostasis and a built-in bi-polar coagulation function at low temperatures3
  • Control: Three ablation and coagulation modes for the desired tissue effect1,2

The ARIS COBLATION Wand is designed specifically for the WEREWOLF ENT Controller. Featuring easy and intuitive set-up,5 the integrated pump is designed to provide consistent saline delivery for efficient plasma formation.6

Technical Details

Single-step insertion

Cottle tip creates an incision and provides a channel for submucosal access, without the need for additional instrumentation.4

Designed to reduce clogging*

Large, single-opening electrode is designed to break down tissue on all exposed surfaces (including the inner rim), with a tip-clearing stylet tool designed to clear clogs easily.

Controlled thermal effect

A controlled, directional thermal effect (blanching) allows the surgeon to target away from, and preserve, the medial mucosa**7 while providing hemostasis.

Improved shaft diameter

Compared to our TURBINATOR Wand, the ARIS COBLATION Wand features an 18% increase in the internal shaft diameter while offering a 17% reduction in the external shaft diameter.  The ARIS COBLATION Wand is the smallest COBLATION Wand with integrated saline delivery and suction.*

ARIS COBLATION Turbinate Reduction Wand comparison

 

 

References
1. Smith+Nephew 2023.ARIS Targeted Hemostasis. Internal Memo. 10094398 Rev A. 2. Smith+Nephew 2023.Report: Resection Rate Comparison ARIS, TURBINATOR, Medtronic
Shavers. Internal Report. 10093413 Rev B. 3. Smith+Nephew 2023. Report: Thermal Effects Comparison between ARIS™ and TURBINATOR™ settings. Internal Report. 10093576
Rev A. 4. Smith+Nephew 2023.Marketing Claims Report: User Feedback. Internal Report. 10092234 Rev A. 5. Smith+Nephew 2019.Report, Design Validation, Summative Usability
WEREWOLF ENT and HALO Wand. Internal Report. SPMENT-108003-01 Rev B. 6. Smith+Nephew 2023.ARIS Integrated Pump. Internal Memo. 10094400 Rev A.